CS87 PROBE - Nitrex
Search
Close this search box.

- CS87 PROBE -

CS87 PROBE

CS87 PROBE

OXYGEN SENSOR

The CS87™ and CCS 2000™ series of oxygen sensors are designed for measuring the oxygen partial pressure of the furnace atmosphere. The robust design withstands thermal shocks and maximizes service life. A self-cleaning mechanism maintains a permanently clean surface between the zirconium dioxide and external electrode, always ensuring accurate signal detection. The modular construction allows easy disassembly/assembly and fast parts replacement.

Documents

FEATURES & BENEFITS

  • Easily installed and connected to your equipment
  • Modular construction allows easy disassembly/assembly and fast parts replacement
  • Robust design withstands thermal shocks
  • Self-cleaning mechanism ensures constantly accurate signal detection
  • Accuracy +/- 0.05 weight percent carbon in normal operating range
  • Response time of less than 1.0 second

SYSTEM CHARACTERISTICS

Carbon Sensor CS 85/87
Available lengths: 400 mm - 1,500 mm (16-59")
Outer tube diameter: 22 mm (3/4") and 27 mm (1")
O2- measuring range: 1 - 1024 bar
Temperature range: 600 °C - 1,100 °C (1,112-2,012 °F)
Thermocouple: Type S/Pt10RhPt
Reference air: Approx. 5-10 l/h (0.18-0.35 CFH)
Ambient air: Max. 80 ˚C (176 ˚F)
Ceramic Carbon Sensor CCS 2000
Available lengths: 700 mm - 900 mm (27-35")
Outer tube diameter: 30 mm (1.18")
O2- measuring range: 1 - 1024 bar
Temperature range: 600 °C - 1,100 °C (1,112-2,012 °F)
Thermocouple: Type S / Pt10RhPt
Reference air: Approx. 5-10 l/h (0.18-0.35 CFH)
Ambient air: Max. 80 ˚C (176 ˚F)